Description
40054797 JUKI High-Speed Chip Shooter KE2070, High-Speed Flexible Mounter KE2080/2080R Operation Manual II (For Programmers and Administrators) Contents:
- Chapter 1: Overview of the Machine
- Introduction
- Features
- System configuration
- KE-2070 system configuration
- KE-2070C system configuration
- KE-2080 system configuration
- KE-2080R system configuration
- Configuration of each device of the machine
- Configuration of the machine
- Configuration of the head unit
- Configuration of the ATC unit (Automatic tool changer)
- Nozzle
- Configuration of the OCC
- Configuration of the VCS
- Handling an HMS
- Mechanical specifications
- Applicable components and packaging styles
- Printed circuit board specifications
- Centering system
- X, Y, Z, and θ axes descriptions
- Configuration of the machine
- Menus and Commands
- Idle mode
- File Operations
- New
- Opening a file (to load a file)
- Saving a file
- Saving a file with the desired name
- File Management [Explorer]
- Default Folder
- Printer Setup
- Control Data Management, Save Machine Data and Save Image Data
- Removing the hardware in safety
- Updating the Drive C
- Chapter 2: Creating a Production Program
- Flowchart
- Options
- User Level
- Changing the user level
- User Group Environmental Settings
- Date and Time Setting
- User Level
- Preparation of a Production Program
- Starting up the Program Editor
- Procedure for creating a production program
- PWB data
- Basic setting
- Dimension setup
- Placement data
- Viewing the placement data screen
- Entry items
- Component data
- Viewing the component data screen
- Creating of component data
- Pick data
- “Pick” data screen display
- Setting items
- Vision data
- “Vision” data screen display
- Setting items
- Element
- Vision Control
- Light Control data
- General-Purpose Vision Components
- Overview of a general-purpose vision component
- Simple Input: Quick Entry of Vision Data on a General-Purpose Vision Component
- Specifications of a general-purpose vision component
- Procedure for Creating Data on a General-Purpose Vision Component
- Data Entry Items
- Component Viewer
- Checking the status of data completion
- Line coherence check
- Optimization
- Conditions setting for optimization
- Component supply count
- Setting the optimization conditions
- Executing the Optimization function
- Executing the Optimization function
- Saving a file
- Checking the divided component placement data
- Nozzle layout
- Feeder layout
- Conditions setting for optimization
- Other Functions
- Editing
- “Edit” menu
- Teaching
- How to use the Handheld Operating Device (HOD)
- Teaching coordinates
- Teaching a mark
- Environment setting
- Machine operation
- Transport
- Measurement
- Inspection
- Confirmation
- Management
- Teaching a component
- Help
- Exit.
- Editing
- Chapter 3 Production.
- Overview
- Production mode.
- Production flowchart
- Production Screen
- Starting up the Production screen.
- Production conditions screen
- Common setting items
- Individual setting items
- Start of production
- “Production status” screen
- Production I/O Status.
- Pause
- Suspending PWB production
- End of production
- Production Management Information
- Production management information
- Production information
- Conveyor status
- Production idle screen
- Production screen
- Tool
- Setting the number of components
- Operation option
- Modifying data
- Automatic PWB width adjustment.
- Retry list
- Displaying the “Retry list” at end of production.
- Retry list displayed during PWB production
- Pick position correction.
- Checking
- Overview
Chapter 4 Other Functions
- Database
- Flexline Database
- How to Use a Flexline Database
- Starting Up the Database
- Creating/Editing Component Data (Including Vision Data)
- Package Type
- Search
- Tools
- Creating Vision Data
- Quitting the Database
- IS Component Database
- How to Use the IS Component Database
- Export component data to the IS component database
- Search
- Flexline Database
- Operation Option
- Overview
- Detailed Setting Items
- Setting the Teaching option
- Setting the Production (Display) option
- Setting the Production (Function) options
- Setting the Production (Function2) option
- Setting the Production (Pause) option
- Setting the Production (Check) option
- Setting the Function enable option
- Setting the Production (Function 3) option
- Setting the option on the “Production (Pause 2)” tab
- Machine Management Information
- Machine Setup
- Overview
- Starting Up or Exiting the Machine Setup Utility
- Starting up the Machine setup utility
- Exiting the Machine setup utility
- File
- Registered nozzle no table
- Read Nzl. data (read nozzle data)
- Setting Group
- ATC nozzle Setup
- Vacuum value without nozzle
- Reference pin position
- Shape clamp position
- MTC shuttle pick position
- MTS position offset
- Component reject position
- IC Collection Belt position
- Head Wait Position
- Device enable
- Online connection
- PWB conveyor
- Signal light
- Bad mark sensor threshold
- Coplanarity
- VCS Cleanliness Check
- Check CAL Block Cleanliness
- Laser Unit Interference Check
- Setting two-dimensional code position on a PWB
- Setting PWB Barcode Recognition for Placement Monitor
- Network settings of the Placement Monitor
- Mechanical Setup
- Manual Control
- Overview
- Starting Up or Quitting the Manual Control Utility
- Starting up the Manual control utility
- Quitting the Manual control utility
- Head control menu
- Laser image display
- Self Calibration
- Overview
- Set-up Group
- Laser/Sensor Height
- Rotation Center of the Nozzle
- Head offset
- VCS Offset
- Vacuum Calibration
- FCS (optional)
- Others
- Log Tool
- Log Tool
- Automatic Log Recording Function
- Automatic log obtaining function to be executed if an error occurs.
- Automatically obtaining a log file on production performed immediately before the system pauses
- What to do at power failure.
- Uninterruptible Power Supplies (UPS)
- Corrective action at power failure
- Recovery operation after power failure (Turning on the machine)
- Log Tool
Chapter 5 Daily maintenance
- List of Daily Routine Checks
- Checking Each Part
- Air pressure
- Option filter
- Piping and joint
- Each unit air cylinder
- Air filter (common to the LNC head and the IC head)
- Transport belt
- Transport pulley
- Gas spring
- Stopper chip
- Cables and connectors
- Vacuum filter (optional)
- Cleaning
- XY axis direct drive unit
- Transport sensors
- CAL block
- Laser align sensor (LNC60/FMLA)
- EPV61/62 (Placement monitor option)
- VCS unit
- Nozzle
- Nozzle outer
- ATC Unit
- Feeder bank
- Overall feeder exchange trolley (optional)
- CVS (Component Verification System) (Option)
- OCC (Polarizing filter)
- Coplanarity sensor
- Load control unit (optional)
- Fan motor filter
- Lubrication
- XY-shaft direct drive unit
- Transport screw shaft (Shaft)
- Transport guide shaft
- PWB stopper part
- Ball screws and spline shaft (Head part)
- Support table
- Overall feeder exchange trolley (optional)
- Replacing the UPS Battery with a New One
- Removing the UPS
- Replacing Batteries
- How to discard a used battery
- Consumable Parts List
- Parts Recommended to Be Replaced on a Regular Basis
Chapter 6 Operating of Troubleshooting
- Component Placement Errors
- Component placement errors occur over the entire board (this error occurs on each board repeatedly)
- Component placement positions are shifted in various directions over the entire board (Coordinates are shifted in the different way depending on a board)
- A component placement error occurs at only part of a board
- Only a certain type of component is placed at the wrong position
- Component placement angle error
- Component Pick-Up Errors
- Laser Recognition (Component Recognition) Errors
- Nozzle Attachment/Detachment Error
- Mark (BOC Mark/IC Mark) Recognition Errors
- Vision Recognition Errors
- Other Errors