40054797 JUKI High-Speed Chip Shooter KE2070, High-Speed Flexible Mounter KE2080/2080R Operation Manual II (For Programmers and Administrators) – E016

20.00$

Description

Explore the comprehensive JUKI High-Speed Chip Shooter KE2070 and Flexible Mounter KE2080/2080R Operation Manual II, tailored for programmers and administrators. This detailed guide covers everything from machine overview, configuration, and device setup, to creating production programs, daily maintenance tips, and troubleshooting techniques, ensuring optimal usage and maintenance of your JUKI SMT equipment

Description

40054797 JUKI High-Speed Chip Shooter KE2070, High-Speed Flexible Mounter KE2080/2080R Operation Manual II (For Programmers and Administrators) Contents:

  1. Chapter 1: Overview of the Machine
    • Introduction
    • Features
    • System configuration
      • KE-2070 system configuration
      • KE-2070C system configuration
      • KE-2080 system configuration
      • KE-2080R system configuration
    • Configuration of each device of the machine
      • Configuration of the machine
        • Configuration of the head unit
        • Configuration of the ATC unit (Automatic tool changer)
        • Nozzle
        • Configuration of the OCC
        • Configuration of the VCS
        • Handling an HMS
      • Mechanical specifications
      • Applicable components and packaging styles
      • Printed circuit board specifications
      • Centering system
      • X, Y, Z, and θ axes descriptions
    • Menus and Commands
    • Idle mode
    • File Operations
      • New
      • Opening a file (to load a file)
      • Saving a file
      • Saving a file with the desired name
      • File Management [Explorer]
      • Default Folder
      • Printer Setup
      • Print
      • Control Data Management, Save Machine Data and Save Image Data
      • Removing the hardware in safety
      • Updating the Drive C
  2. Chapter 2: Creating a Production Program
  • Flowchart
  • Options
    • User Level
      • Changing the user level
      • User Group Environmental Settings
    • Date and Time Setting
  • Preparation of a Production Program
    • Starting up the Program Editor
    • Procedure for creating a production program
    • PWB data
      • Basic setting
      • Dimension setup
    • Placement data
      • Viewing the placement data screen
      • Entry items
    • Component data
      • Viewing the component data screen
      • Creating of component data
    • Pick data
      • “Pick” data screen display
      • Setting items
    • Vision data
      • “Vision” data screen display
      • Setting items
      • Element
      • Vision Control
      • Light Control data
    • General-Purpose Vision Components
      • Overview of a general-purpose vision component
      • Simple Input: Quick Entry of Vision Data on a General-Purpose Vision Component
      • Specifications of a general-purpose vision component
      • Procedure for Creating Data on a General-Purpose Vision Component
      • Data Entry Items
      • Component Viewer
    • Checking the status of data completion
    • Line coherence check
  • Optimization
    • Conditions setting for optimization
      • Component supply count
      • Setting the optimization conditions
    • Executing the Optimization function
      • Executing the Optimization function
      • Saving a file
      • Checking the divided component placement data
      • Nozzle layout
      • Feeder layout
  • Other Functions
    • Editing
      • “Edit” menu
    • Teaching
      • How to use the Handheld Operating Device (HOD)
      • Teaching coordinates
      • Teaching a mark
    • Environment setting
    • Machine operation
      • Transport
      • Measurement
      • Inspection
      • Confirmation
      • Management
      • Teaching a component
    • Print
    • Help
    • Exit.
  1. Chapter 3 Production.
    • Overview
      • Production mode.
      • Production flowchart
      • Production Screen
        • Starting up the Production screen.
        • Production conditions screen
          • Common setting items
          • Individual setting items
        • Start of production
          • “Production status” screen
          • Production I/O Status.
          • Pause
          • Suspending PWB production
          • End of production
      • Production Management Information
        • Production management information
        • Production information
        • Conveyor status
          • Production idle screen
          • Production screen
      • Tool
        • Setting the number of components
        • Operation option
        • Modifying data
        • Automatic PWB width adjustment.
        • Retry list
          • Displaying the “Retry list” at end of production.
          • Retry list displayed during PWB production
          • Pick position correction.
      • Checking

Chapter 4 Other Functions

  • Database
    • Flexline Database
      • How to Use a Flexline Database
      • Starting Up the Database
      • Creating/Editing Component Data (Including Vision Data)
      • Package Type
      • Search
      • Tools
      • Creating Vision Data
      • Print
      • Quitting the Database
    • IS Component Database
      • How to Use the IS Component Database
      • Export component data to the IS component database
      • Search
  • Operation Option
    • Overview
    • Detailed Setting Items
      • Setting the Teaching option
      • Setting the Production (Display) option
      • Setting the Production (Function) options
      • Setting the Production (Function2) option
      • Setting the Production (Pause) option
      • Setting the Production (Check) option
      • Setting the Function enable option
      • Setting the Production (Function 3) option
      • Setting the option on the “Production (Pause 2)” tab
  • Machine Management Information
  • Machine Setup
    • Overview
    • Starting Up or Exiting the Machine Setup Utility
      • Starting up the Machine setup utility
      • Exiting the Machine setup utility
    • File
      • Registered nozzle no table
      • Read Nzl. data (read nozzle data)
    • Setting Group
      • ATC nozzle Setup
      • Vacuum value without nozzle
      • Reference pin position
      • Shape clamp position
      • MTC shuttle pick position
      • MTS position offset
      • Component reject position
      • IC Collection Belt position
      • Head Wait Position
      • Device enable
      • Online connection
      • PWB conveyor
      • Signal light
      • Bad mark sensor threshold
      • Coplanarity
      • VCS Cleanliness Check
      • Check CAL Block Cleanliness
      • Laser Unit Interference Check
      • Setting two-dimensional code position on a PWB
      • Setting PWB Barcode Recognition for Placement Monitor
      • Network settings of the Placement Monitor
    • Mechanical Setup
  • Manual Control
    • Overview
    • Starting Up or Quitting the Manual Control Utility
      • Starting up the Manual control utility
      • Quitting the Manual control utility
    • Head control menu
    • Laser image display
  • Self Calibration
    • Overview
    • Set-up Group
      • Laser/Sensor Height
      • Rotation Center of the Nozzle
      • Head offset
      • VCS Offset
      • Vacuum Calibration
      • FCS (optional)
    • Others
      • Log Tool
        • Log Tool
      • Automatic Log Recording Function
        • Automatic log obtaining function to be executed if an error occurs.
        • Automatically obtaining a log file on production performed immediately before the system pauses
      • What to do at power failure.
        • Uninterruptible Power Supplies (UPS)
        • Corrective action at power failure
        • Recovery operation after power failure (Turning on the machine)

Chapter 5 Daily maintenance

  • List of Daily Routine Checks
  • Checking Each Part
    • Air pressure
    • Option filter
    • Piping and joint
    • Each unit air cylinder
    • Air filter (common to the LNC head and the IC head)
    • Transport belt
    • Transport pulley
    • Gas spring
    • Stopper chip
    • Cables and connectors
    • Vacuum filter (optional)
  • Cleaning
    • XY axis direct drive unit
    • Transport sensors
    • CAL block
    • Laser align sensor (LNC60/FMLA)
    • EPV61/62 (Placement monitor option)
    • VCS unit
    • Nozzle
    • Nozzle outer
    • ATC Unit
    • Feeder bank
    • Overall feeder exchange trolley (optional)
    • CVS (Component Verification System) (Option)
    • OCC (Polarizing filter)
    • Coplanarity sensor
    • Load control unit (optional)
    • Fan motor filter
  • Lubrication
    • XY-shaft direct drive unit
    • Transport screw shaft (Shaft)
    • Transport guide shaft
    • PWB stopper part
    • Ball screws and spline shaft (Head part)
    • Support table
    • Overall feeder exchange trolley (optional)
  • Replacing the UPS Battery with a New One
    • Removing the UPS
    • Replacing Batteries
    • How to discard a used battery
  • Consumable Parts List
  • Parts Recommended to Be Replaced on a Regular Basis

Chapter 6 Operating of Troubleshooting

  • Component Placement Errors
    • Component placement errors occur over the entire board (this error occurs on each board repeatedly)
    • Component placement positions are shifted in various directions over the entire board (Coordinates are shifted in the different way depending on a board)
    • A component placement error occurs at only part of a board
    • Only a certain type of component is placed at the wrong position
    • Component placement angle error
  • Component Pick-Up Errors
  • Laser Recognition (Component Recognition) Errors
  • Nozzle Attachment/Detachment Error
  • Mark (BOC Mark/IC Mark) Recognition Errors
  • Vision Recognition Errors
  • Other Errors

Brand

JUKI

JUKI SMT Pick and Place Machine Maintenance Guide / JUKI Instruction Manual / JUKI Electrical Schematics / JUKI Wire Diagram / JUKI SMT Machine Manuals / JUKI Feeder Part List / JUKI Nozzle List
JUKI SMT Pick and Place Machine Maintenance Guide / JUKI Instruction Manual / JUKI Electrical Schematics / JUKI Wire Diagram / JUKI SMT Machine Manuals / JUKI Feeder Part List / JUKI Nozzle List