| Model | BF-Planet-XII |
| Features | In-line 2D AOI |
| Max PCB size is 330x250mm for BF-Planet-XII, |
| 500x460mm for BF-FrontierII, 870x686mm for BF-10Z |
| BF-Planet-XII’s scanning time is only 4 seconds |
| BF-Planet-XII’s compact body of only 60cm width |
| System Specifications |
| Resolution | 10um |
| Board Size | 50×60 – 250×330mm, 2×2.4 – 10×13in. |
| Board Thickness | 0.6 – 3.2mm, 24 – 126mils |
| Board Warp | +/-2mm, 79mils |
| PCB Clearance | Top: 40mm, 1.57in. Bottom: 40mm, 1.57in. |
| Rotated Component Support | Available for 0 – 359°rotation (unit of 1°) |
| Inspection Categories | Presence/Absence, Misalignment, Tombstone, Reverse, Polarity, Bridge, Foreign material, Absence of solder, Insuffi cient solder, Lifted lead, Lifted Chip, and Fillet defect. Each defect name can be changed freely by system function |
| Tact Time* 1 * 2 | Approx. 18sec. (250×330mm) |
| Image Scanning Time* 1 | Approx. 9sec. (250×330mm) |
| Camera (Image Processing) | Line color CCD camera |
| Lighting | LED lighting system |
| Transfer Conveyor Method | Flat belt transfer |
| Transfer Conveyor Height | 900+/-20mm, 36+/-0.8in |
| Transfer Conveyor Width Adjustment | Manual |
| Operating System | Windows XP English Version |
| Optional System | BF-Editor / BF-RP1 / BF-Monitor / BF-View |
| Optional | 2D Barcode Recognition, Journal Printer, Automatic Transfer Conveyor Width Adjustment |
*1 If PCB size is smaller than 250x330mm, Image scannig time will be shorter than this values. *2 Including Image Scanning Time |
| Installation Specifications |
| Electric Power Requirement | Single Phase ,100 – 120V / 200 – 240V +/-10%, 50/60Hz, 500VA |
| Air Requirement | 0.5MPa, 5L/min (ANR), 73PSI, 0.18CFM |
| Usage Environment | 15°C(59F) – 30°C(86F) / 15 – 80% RH (Non-condensing) |
| Noise Level | 57.5dB |
| Dimensions W x D x H | 600 × 915 × 1270mm, 24 × 36 × 50in. |
| Weight | Approx. 275kg, 607lbs |